An onsite skylight survey and inspection was made on 4/4/2017 by Skylight Specialists, Inc., represented by Danny Packard.

Fire Place area  – One (1) 8’ x 8’ (nominal) glass, pyramid, curb mount, original skylight.

  • Glazing: Glass, heat strengthened over laminate, green, insulated unit, fall protected.
  • Structure: Adequate spacing and size structural aluminum frame.
  • Anchors: Adequate anchor size and count around perimeter.
  • Curbs: Adequate height and flashing in good shape.
  • Evaluation: Skylight is in acceptable condition no work needed.
  • Flashing: Metal flashing; adequate in condition.
  • Rating: 7 of 10
  • Expected Life Span: 10-25 years.
  • Recommendation: None.

Porte Cochere – Three (3) 4’ x 36’ (nominal) acrylic, barrel vault, curb mount, original skylight.

  • Glazing: Acrylic, clear, single glazed, not fall protected.
  • Structure: Adequate spacing and size structural aluminum frame.
  • Anchors: Missing anchors.
  • Curbs: Adequate height. Skylight is too large for curbs and needs be resized.
  • Evaluation: Skylight is crazing and cracked and in poor condition.
  • Flashing: Matches existing roof and in good condition.
  • Rating: 2.5 of 10
  • Expected Life Span: 1-3 years.
  • Recommendation: All three skylights should be replaced due to numerous cracks and holes. Resize to fit curb size.

Bar – One (1) 7’ down slope x 38’ (nominal) glass with reflective film, single slope, structural, original skylight.

skylight inspection DoubleTree 24429-091153608
  • Glazing: Glass with reflective film, heat strengthened over laminate, Green tint, insulated unit, fall protected.
  • Structure: Adequate spacing and size structural aluminum frame.
  • Anchors: Adequate anchor size and count around perimeter.
  • Curbs: N/A.
  • Flashing: Metal flashing; adequate in condition.
  • Evaluation: Skylight is in acceptable condition no work needed.
  • Rating: 7 of 10
  • Expected Life Span: 5-10 years.
  • Recommendation: None at this time – when it starts to leak at that time wet seal.

Back entrance – One (1) 6’ down slope x 34’ (nominal) glass, single slope, structural, original skylight.

skylight inspection DoubleTree 24429-092817664
  • Glazing: Glass, heat strengthened over laminate, green tint, insulated unit, fall protected.
  • Structure: Adequate spacing and size structural aluminum frame.
  • Anchors: Adequate anchor size and count around perimeter.
  • Curbs: Adequate height and flashing in good shape.
  • Flashing: Adequate in condition.
  • Evaluation: Skylight is in acceptable but one pane is cracked and needs to be replaced.
  • Rating: 5 of 10
  • Expected Life Span: 5-10 years.
  • Recommendation: One pane of glass is cracked and needs to be replaced—wet seal entire skylight at time of replacement.